-- Version info
--
-- Version 0.1 Created 2011.03.09 by wuliang
-- Copyright(c) 2003-2007 by RAISECOM TECH, Ltd.
-- =======================================================================

-- ===========================================================================

--     111
-- RAISECOM base management objects
--

RAISECOM-PON-DEVICE-MIB DEFINITIONS ::= BEGIN

    IMPORTS
		MODULE-IDENTITY,
		OBJECT-TYPE,
		NOTIFICATION-TYPE ,
		Integer32,
		IpAddress,
		Unsigned32
			FROM SNMPv2-SMI
		DisplayString,
		TimeStamp,
		RowStatus,
		TruthValue,
		MacAddress
			FROM SNMPv2-TC
		EnableVar
			FROM SWITCH-TC
	    SlotIndex,
	    PONDeviceType,
	    PONDeviceCardType
	        FROM RAISECOM-PONSERIES-TC
		raisecomAgent
			FROM RAISECOM-BASE-MIB;


	raisecomdeviceMgt    MODULE-IDENTITY
		LAST-UPDATED 	"201103091000Z"
		ORGANIZATION 	"RAISECOM TECH, Ltd."
		CONTACT-INFO 	"www.raisecom.com"
		DESCRIPTION
		    "The MIB module defining objects for device management"
		::= { raisecomAgent  27}

	--groups
	  raisecomNEEquip			OBJECT IDENTIFIER ::= {raisecomdeviceMgt 1}
	  raisecomShelf  			OBJECT IDENTIFIER ::= {raisecomdeviceMgt 2}
	  raisecomSlot  			OBJECT IDENTIFIER ::= {raisecomdeviceMgt 3}
	  raisecomPower 			OBJECT IDENTIFIER ::= {raisecomdeviceMgt 4}
	  raisecomFan   			OBJECT IDENTIFIER ::= {raisecomdeviceMgt 5}
--	  raisecomOutbandMgtPort	OBJECT IDENTIFIER ::= {raisecomdeviceMgt 6}
--	  raisecomConsolePort		OBJECT IDENTIFIER ::= {raisecomdeviceMgt 7}
	  raisecomDeviceAlarm		OBJECT IDENTIFIER ::= {raisecomdeviceMgt 8}
	  raisecomAlarmInput		OBJECT IDENTIFIER ::= {raisecomdeviceMgt 10}
      raisecomCardTemplate      OBJECT IDENTIFIER ::= {raisecomdeviceMgt 11}
	  raisecomCardPower         OBJECT IDENTIFIER ::= {raisecomdeviceMgt 12}

       -- raisecomNEEquip
    raisecomNEType   OBJECT-TYPE
        SYNTAX 		PONDeviceType
        MAX-ACCESS 	read-only
        STATUS current
        DESCRIPTION  "Network element type."
        ::= { raisecomNEEquip 1 }

    raisecomNEAssetID      OBJECT-TYPE
        SYNTAX 		OCTET STRING  (SIZE (0..64))
        MAX-ACCESS 	read-write
        STATUS current
        DESCRIPTION "Asset ID of this network element for the carrier."
        ::= { raisecomNEEquip 2 }

    raisecomNEMfrVendor      OBJECT-TYPE
        SYNTAX 		OCTET STRING  (SIZE(0..64))
        MAX-ACCESS 	read-only
        STATUS current
        DESCRIPTION  "Vendor name for this network element."
        ::= { raisecomNEEquip 3 }

    raisecomNETmptAlarmThreshold      OBJECT-TYPE
        SYNTAX 		INTEGER (0..100)
        MAX-ACCESS 	read-write
        STATUS current
        DESCRIPTION  "Temperature threshold to issure the temperature alarm. The applicability depends on the device type."
        DEFVAL { 70 }
        ::= { raisecomNEEquip 4 }


  --raisecomShelf

   raisecomShelfTable    OBJECT-TYPE
        SYNTAX          SEQUENCE OF  RaisecomShelfEntry
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION     "Shelf management table."
    ::= { raisecomShelf 1 }

    raisecomShelfEntry    OBJECT-TYPE
	SYNTAX          RaisecomShelfEntry
	MAX-ACCESS      not-accessible
    STATUS          current
	DESCRIPTION     "Shelf management table entry."
	INDEX { raisecomShelfId }
    ::= { raisecomShelfTable 1 }

    RaisecomShelfEntry ::= SEQUENCE {
        raisecomShelfId             		Integer32,
        raisecomShelfDescr          		OCTET STRING (SIZE (0..64)),
        raisecomShelfSerialNum      		OCTET STRING (SIZE (0..64)),
        raisecomShelfHwVersion      		OCTET STRING (SIZE (0..64)),
        raisecomShelfLevel           		INTEGER,
        raisecomShelfType                   OCTET STRING (SIZE (0..64)),
        raisecomShelfGenType        		INTEGER,
        raisecomShelfMfrVendor      		OCTET STRING (SIZE (0..64)),
        raisecomShelfAssetID        		OCTET STRING (SIZE (0..64)),
        raisecomShelfTemperature    		INTEGER,
        raisecomShelfSlotNum				Integer32,
        raisecomShelfNMSSlotNum     		INTEGER,
        raisecomShelfPrimaryNMSSlotId   	Integer32,
        raisecomShelfSecondaryNMSSlotId     Integer32,
        raisecomShelfMac                    MacAddress
        }

     raisecomShelfId   OBJECT-TYPE
        SYNTAX          Integer32(0..15)
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Shelf id."
        ::= { raisecomShelfEntry 1 }

     raisecomShelfDescr   OBJECT-TYPE
        SYNTAX          OCTET STRING (SIZE(0..64))
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION      "Shelf description."
        ::= { raisecomShelfEntry 2 }

     raisecomShelfSerialNum   OBJECT-TYPE
        SYNTAX          OCTET STRING (SIZE(0..64))
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Shelf device serial number."
        ::= { raisecomShelfEntry 3 }

     raisecomShelfHwVersion   OBJECT-TYPE
        SYNTAX          OCTET STRING (SIZE(0..64))
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
        		"Shelf hardware version.

                For pizza-box type of device, it indicates version of the device, not of the card.
                For other type of device, it indicates version of the shelf, mainly of the backplane."
        ::= { raisecomShelfEntry 4 }

     raisecomShelfLevel   OBJECT-TYPE
        SYNTAX          INTEGER {
                              	masterShelf(1),
								extendShelf1(2),
								extendShelf2(3),
								extendShelf3(4),
								extendShelf4(5),
								extendShelf5(6),
								extendShelf6(7),
								extendShelf7(8),
								extendShelf8(9)
								}
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Shelf level."
        ::= { raisecomShelfEntry 5 }

      raisecomShelfType   OBJECT-TYPE
        SYNTAX          OCTET STRING (SIZE(0..64))
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Shelf type."
        ::= { raisecomShelfEntry 6 }

      raisecomShelfGenType   OBJECT-TYPE
        SYNTAX          INTEGER {
                              	other(1),
								unknown(2),
								chassis(3),
								backplane(4),
								container(5),
								powerSupply(6),
								fan(7),
								sensor(8),
								module(9),
								port(10),
								stack(11)
								}
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Shelf Species."
        ::= { raisecomShelfEntry 7 }

       raisecomShelfMfrVendor   OBJECT-TYPE
        SYNTAX          OCTET STRING (SIZE(0..64))
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Vendor name for this shelf."
        ::= { raisecomShelfEntry 8 }

        raisecomShelfAssetID   OBJECT-TYPE
        SYNTAX          OCTET STRING (SIZE(0..64))
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION     "Asset ID of this shelf."
        ::= { raisecomShelfEntry 9 }

       raisecomShelfTemperature   OBJECT-TYPE
        SYNTAX          INTEGER (-100..100)
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Temperature of this shelf."
        ::= { raisecomShelfEntry 10 }

       raisecomShelfSlotNum   OBJECT-TYPE
        SYNTAX          Integer32(0..15)
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Number of slots for installing cards in this shelf."
        ::= { raisecomShelfEntry 11 }

        raisecomShelfNMSSlotNum   OBJECT-TYPE
        SYNTAX          INTEGER (1..2)
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Number of slots for management and control cards in this shelf."
        ::= { raisecomShelfEntry 12 }

       raisecomShelfPrimaryNMSSlotId   OBJECT-TYPE
        SYNTAX          Integer32 (0..15)
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Slot for the primary management and control card."
        ::= { raisecomShelfEntry 13 }

       raisecomShelfSecondaryNMSSlotId   OBJECT-TYPE
        SYNTAX          Integer32 (0..15)
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Slot for the secondary management and control card.
                         Valid only when raisecomShelfNMSSlotNum equals to 2."
        ::= { raisecomShelfEntry 14 }

       raisecomShelfMac   OBJECT-TYPE
        SYNTAX          MacAddress
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "The MAC address of this shelf."
        ::= { raisecomShelfEntry 15 }


   -- raisecomCardTemplate

    raisecomCardTemplateTable    OBJECT-TYPE
        SYNTAX                SEQUENCE OF  RaisecomCardTemplateEntry
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION     "Card Template table."
    ::= { raisecomCardTemplate 1 }

    raisecomCardTemplateEntry    OBJECT-TYPE
	SYNTAX          RaisecomCardTemplateEntry
	MAX-ACCESS      not-accessible
    STATUS          current
	DESCRIPTION     "Card template table entry."
	INDEX { raisecomCardType }
    ::= { raisecomCardTemplateTable 1 }

    RaisecomCardTemplateEntry ::=
        SEQUENCE {
        raisecomCardType             	    PONDeviceCardType,
        raisecomCardPanelPortNum         	Integer32(0..16),
        raisecomCardPanelPortTypes          OCTET STRING (SIZE(0..32)),
        raisecomCardPermitedSlots    INTEGER
                }

    raisecomCardType   OBJECT-TYPE
        SYNTAX          PONDeviceCardType
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "The card type of this template."
        ::= { raisecomCardTemplateEntry 1 }

    raisecomCardPanelPortNum   OBJECT-TYPE
        SYNTAX          Integer32(0..16)
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Plane port number of this card-type template."
        ::= { raisecomCardTemplateEntry 2 }

    raisecomCardPanelPortTypes   OBJECT-TYPE
        SYNTAX          OCTET STRING (SIZE(0..32))
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Plane port types  of this type card template."
        ::= { raisecomCardTemplateEntry 3 }

    raisecomCardPermitedSlots   OBJECT-TYPE
        SYNTAX          INTEGER
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "All the slot id of this type card which can be installed."
        ::= { raisecomCardTemplateEntry 4 }

   -- raisecomSlot

    raisecomSlotTable    OBJECT-TYPE
        SYNTAX          SEQUENCE OF  RaisecomSlotEntry
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION     "Card slot management table."
    ::= { raisecomSlot 1 }

    raisecomSlotEntry    OBJECT-TYPE
	SYNTAX          RaisecomSlotEntry
	MAX-ACCESS      not-accessible
    STATUS          current
	DESCRIPTION     "Card slot management table entry."
	INDEX { raisecomSlotId }
    ::= { raisecomSlotTable 1 }

    RaisecomSlotEntry ::=
        SEQUENCE {
        raisecomSlotId             			SlotIndex,
        raisecomSlotDescr         			OCTET STRING (SIZE(0..64)),
        raisecomSlotExpectCardType          PONDeviceCardType,
        raisecomSlotExpectCardDescr         OCTET STRING (SIZE(0..64)),
        raisecomSlotActCardType             PONDeviceCardType,
        raisecomSlotActCardDescr            OCTET STRING (SIZE(0..64)),
        raisecomSlotActCardSerialNum        OCTET STRING (SIZE(0..64)),
        raisecomSlotActCardHwVersion        OCTET STRING (SIZE(0..64)),
        raisecomSlotActCardMfrVendor        OCTET STRING (SIZE(0..64)),
        raisecomSlotActCardAssetID        	OCTET STRING (SIZE(0..64)),
        raisecomSlotActCardState            INTEGER,
        raisecomSlotReboot                  INTEGER,
        raisecomSlotSupportCardTypes         OCTET STRING (SIZE(0..128)),
        raisecomSlotActCardSwVersion        OCTET STRING (SIZE(0..64)),
        raisecomSlotPowerState               INTEGER
        }


     raisecomSlotId     OBJECT-TYPE
        SYNTAX          SlotIndex
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Slot id."
        ::= { raisecomSlotEntry 1 }

     raisecomSlotDescr   OBJECT-TYPE
        SYNTAX          OCTET STRING (SIZE(0..64))
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION      "Slot description."
        ::= { raisecomSlotEntry 2 }

     raisecomSlotExpectCardType    OBJECT-TYPE
        SYNTAX          PONDeviceCardType
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION     "Expected card type."
        ::= { raisecomSlotEntry 3 }

     raisecomSlotExpectCardDescr   OBJECT-TYPE
        SYNTAX          OCTET STRING (SIZE(0..64))
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION     "Description of the expected card. Currently unused."
        ::= { raisecomSlotEntry 4 }

   	raisecomSlotActCardType     OBJECT-TYPE
        SYNTAX          PONDeviceCardType
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Type of the card actually installed."
        ::= { raisecomSlotEntry 5 }

    raisecomSlotActCardDescr   OBJECT-TYPE
        SYNTAX          OCTET STRING (SIZE(0..64))
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION     "Description of the card actually installed. The applicability depends on the card type."
        ::= { raisecomSlotEntry 6 }

    raisecomSlotActCardSerialNum   OBJECT-TYPE
        SYNTAX          OCTET STRING (SIZE(0..64))
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Serial number of the card actually installed."
        ::= { raisecomSlotEntry 7 }

    raisecomSlotActCardHwVersion   OBJECT-TYPE
        SYNTAX          OCTET STRING (SIZE(0..64))
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Hardware version of the card actually installed."
        ::= { raisecomSlotEntry 8 }

    raisecomSlotActCardMfrVendor   OBJECT-TYPE
        SYNTAX          OCTET STRING (SIZE(0..64))
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Vender name of the card actually installed."
        ::= { raisecomSlotEntry 9 }

    raisecomSlotActCardAssetID   OBJECT-TYPE
        SYNTAX          OCTET STRING (SIZE(0..64))
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION     "Asset id of the card actually installed."
        ::= { raisecomSlotEntry 10 }

    raisecomSlotActCardState    OBJECT-TYPE
        SYNTAX          INTEGER {
                              	lost(1),
                              	poweroffed(13),
                              	offline(2),
                              	type-identifying(11),
                              	nonprovision(3),
                              	typemismatched(4),
                              	generalfault(5),
                              	versionmismatched(6),
                              	initialized(12),
                              	configloading(7),
                              	configfailed(8),
                              	inservice(9),
								standby(10)
								}
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Working state of the card actually installed."
        ::= { raisecomSlotEntry 11 }

    raisecomSlotReboot    OBJECT-TYPE
        SYNTAX          INTEGER {
                              	cold(1),
								warm(2)
								}
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION     "Reboot the card. Result of reading this attribute is undefined."
        ::= { raisecomSlotEntry 12 }

    raisecomSlotSupportCardTypes    OBJECT-TYPE
        SYNTAX          OCTET STRING (SIZE(0..128))
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "The slots on which the card type can be installed"
        ::= { raisecomSlotEntry 13 }

   raisecomSlotActCardSwVersion   OBJECT-TYPE
        SYNTAX          OCTET STRING (SIZE(0..64))
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "softerware version of the card actually installed."
        ::= { raisecomSlotEntry 14 }

   raisecomSlotPowerState    OBJECT-TYPE
        SYNTAX          INTEGER {
                              	on(1),
                              	off(2)
								}
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION     "set card power-save state on the slot."
        ::= { raisecomSlotEntry 15 }

  -- raisecomPower

   raisecomPowerDeviceTable    OBJECT-TYPE
        SYNTAX          SEQUENCE OF  RaisecomPowerDeviceEntry
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION     "Power device management table."
    ::= { raisecomPower 1 }

    raisecomPowerDeviceEntry    OBJECT-TYPE
	SYNTAX          RaisecomPowerDeviceEntry
	MAX-ACCESS      not-accessible
    STATUS          current
	DESCRIPTION     "Power device management table entry."
	INDEX { raisecomPowerDeviceIndex  }
    ::= { raisecomPowerDeviceTable 1 }

    RaisecomPowerDeviceEntry  ::=
        SEQUENCE {
        raisecomPowerDeviceIndex           			   SlotIndex,
        raisecomPowerDeviceInputType                   INTEGER,
 --       raisecomPowerExpectType                        INTEGER,
--        raisecomPowerActualType                        INTEGER,
 --       raisecomPowerManageable                        INTEGER,
--        raisecomPowerSwVersion                         OCTET STRING (SIZE(0..16)),
--        raisecomPowerHwVersion                         OCTET STRING (SIZE(0..16)),
  --      raisecomPowertemperature                       Integer32,
        raisecomPowerInputvol                          Integer32,
        raisecomPowerInputvolalarmState                INTEGER,
        raisecomPowerInputvolMinlowerVolThres          Integer32,
        raisecomPowerInputvolMinupperVolThres          Integer32,
        raisecomPowerInputvolMajlowerVolThres          Integer32,
        raisecomPowerInputvolMajupperVolThres          Integer32,
        raisecomPowerInputvolCrilowerVolThres          Integer32,
        raisecomPowerInputvolCriupperVolThres          Integer32,
        raisecomPowerTemperatureThres                  Integer32
--        raisecomPowerSerialNum                         OCTET STRING (SIZE(0..64))
        }

     raisecomPowerDeviceIndex      OBJECT-TYPE
        SYNTAX          SlotIndex
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Power device id."
        ::= { raisecomPowerDeviceEntry 1 }

     raisecomPowerDeviceInputType     OBJECT-TYPE
        SYNTAX          INTEGER  {
									unknown(1),
									ac(2),
									dc48(3),
									dc24(4),
									dc12(5),
									null(6),
									ac220(7),
									ac110(8)
								  }
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Input type of this power device. Null value means that this power device is plugged out."
        ::= { raisecomPowerDeviceEntry 2 }

--     raisecomPowerExpectType     OBJECT-TYPE
--        SYNTAX          INTEGER  {
--									any(1),
--									subPwrmAc(2),
--									subPwrmDc(3)
--								  }
 --       MAX-ACCESS      read-write
--        STATUS          current
--        DESCRIPTION     "Expected power type,the default type is any(1), not used in V2.0"
--        ::= { raisecomPowerDeviceEntry 3 }

 --    raisecomPowerActualType     OBJECT-TYPE
 --       SYNTAX          INTEGER  {
--									unknown(0),
--									subPwrmAc(2),
--									subPwrmDc(3),
--									subPwriiAc(4),
--									null(5)
--								  }
 --       MAX-ACCESS      read-only
 --       STATUS          current
 --       DESCRIPTION     "the actual power type ,Null value means that this power device is plugged out."
--        ::= { raisecomPowerDeviceEntry 4 }


--     raisecomPowerManageable     OBJECT-TYPE
 --       SYNTAX          INTEGER  {
--									yes(1),
--									no(2)
--								 }
 --       MAX-ACCESS      read-only
 --       STATUS          current
 --       DESCRIPTION     "Whether it is manageable by the NMS of this type power, not used in V2.0."
 --       ::= { raisecomPowerDeviceEntry 5 }

 --    raisecomPowerSwVersion     OBJECT-TYPE
 --       SYNTAX          OCTET STRING (SIZE(0..16))
  --      MAX-ACCESS      read-only
  --      STATUS          current
 --       DESCRIPTION     "the software version of this type power."
  --      ::= { raisecomPowerDeviceEntry 6 }

  --   raisecomPowerHwVersion     OBJECT-TYPE
  --      SYNTAX          OCTET STRING (SIZE(0..16))
 --       MAX-ACCESS      read-only
 --       STATUS          current
 --       DESCRIPTION     "the hardware version of this type power."
 --       ::= { raisecomPowerDeviceEntry 7 }


--     raisecomPowertemperature     OBJECT-TYPE
--        SYNTAX          Integer32(-100..150)
--        MAX-ACCESS      read-only
--        STATUS          current
--        DESCRIPTION     "The temperature of this power device,it is only meaningful for the manageable power,
--                         this node doesnot used in V2.0."
 --       ::= { raisecomPowerDeviceEntry 8 }

     raisecomPowerInputvol     OBJECT-TYPE
        SYNTAX          Integer32(-100..300)
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "The input voltage of this power device, it is only meaningful for the manageable power."
        ::= { raisecomPowerDeviceEntry 9 }

     raisecomPowerInputvolalarmState     OBJECT-TYPE
        SYNTAX          INTEGER {
        						   normal(1),
        						   lowMin(2),
        						   lowMaj(3),
        						   lowCri(4),
        						   uppMin(5),
        						   uppMaj(6),
        						   uppCri(7)
        						}
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "The input voltage alarm state of the power device, it is only meaningful for the manageable power."
        ::= { raisecomPowerDeviceEntry 10 }

     raisecomPowerInputvolMinlowerVolThres     OBJECT-TYPE
        SYNTAX          Integer32(0..300)
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION     "The input voltage lower threshold of the Minor alarm , it is only meaningful for the manageable power."
        ::= { raisecomPowerDeviceEntry 11 }

     raisecomPowerInputvolMajlowerVolThres     OBJECT-TYPE
        SYNTAX          Integer32(0..300)
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION     "The input voltage lower threshold of the Major alarm,
                          it is only meaningful for the manageable power ."
        ::= { raisecomPowerDeviceEntry 12 }

     raisecomPowerInputvolCrilowerVolThres     OBJECT-TYPE
        SYNTAX          Integer32(0..300)
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION     "The input voltage lower threshold of the Critical alarm ,
                          it is only meaningful for the manageable power."
        ::= { raisecomPowerDeviceEntry 13 }

     raisecomPowerInputvolMinupperVolThres     OBJECT-TYPE
        SYNTAX          Integer32(0..300)
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION     "The input voltage upper threshold of the Minor alarm ,
                          it is only meaningful for the manageable power."
        ::= { raisecomPowerDeviceEntry 14 }

     raisecomPowerInputvolMajupperVolThres     OBJECT-TYPE
        SYNTAX          Integer32(0..300)
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION     "The input voltage upper threshold of the Major alarm ,
                          it is only meaningful for the manageable power."
        ::= { raisecomPowerDeviceEntry 15 }

     raisecomPowerInputvolCriupperVolThres     OBJECT-TYPE
        SYNTAX          Integer32(0..300)
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION     "The input voltage upper threshold of the Critical alarm ,
                          it is only meaningful for the manageable power."
        ::= { raisecomPowerDeviceEntry 16 }

     raisecomPowerTemperatureThres     OBJECT-TYPE
        SYNTAX          Integer32(0..100)
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION     "The temperature threshold of the power device ,
                         it is only meaningful for the manageable power, not used in V2.0."
        DEFVAL {85}
        ::= { raisecomPowerDeviceEntry 17 }


--       raisecomPowerSerialNum     OBJECT-TYPE
--        SYNTAX          OCTET STRING (SIZE(0..64))
--        MAX-ACCESS      read-only
--        STATUS          current
--        DESCRIPTION     "the serial nums of  this power device."
--        ::= { raisecomPowerDeviceEntry 18 }

-- raisecomPowerOutputTable
     raisecomPowerOutputTable    OBJECT-TYPE
        SYNTAX          SEQUENCE OF  RaisecomPowerOutputEntry
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION     "Power device output management table."
    ::= { raisecomPower 2 }

    raisecomPowerOutputEntry    OBJECT-TYPE
	SYNTAX          RaisecomPowerOutputEntry
	MAX-ACCESS      not-accessible
    STATUS          current
	DESCRIPTION     "Power device output management table entry."
	INDEX { raisecomPowerDeviceIndex, raisecomPowerOutputType }
    ::= { raisecomPowerOutputTable 1 }

    RaisecomPowerOutputEntry ::=
        SEQUENCE {
        raisecomPowerOutputType             			 INTEGER,
        raisecomPowerStatus                				 INTEGER,
        raisecomPowerOutputvol                           Integer32,
        raisecomPowerOutputvollowerThres                 Integer32,
        raisecomPowerOutputvolupperThres                 Integer32
        }

     raisecomPowerOutputType     OBJECT-TYPE
        SYNTAX          INTEGER {
        							rcPowerOther(1),
                                 	rcPower3v(2),
									rcPower5v(3),
									rcPower12v(4),
									rcPower-48v(5)
							    }
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Output type of the power device."
        ::= { raisecomPowerOutputEntry 1 }

     raisecomPowerStatus     OBJECT-TYPE
        SYNTAX          INTEGER  {
									normal(1),
									abnormal(2),
									null(3),
									highAlarm(4),
									lowAlarm(5)
								}
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Output status of this power output. Null value means that this output port does not exist."
        ::= { raisecomPowerOutputEntry 2 }

     raisecomPowerOutputvol     OBJECT-TYPE
        SYNTAX          Integer32(-1000..1000)
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Output voltage of the power,it is only meaningful for the manageable power,
        				for the 5v output voltage ,the unit is 0.01v; for the -48V output voltage, the unit is 0.1v"
        ::= { raisecomPowerOutputEntry 3 }

     raisecomPowerOutputvollowerThres     OBJECT-TYPE
        SYNTAX          Integer32(-500..500)
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION     "The threshold of the low output voltage  alarm,it is only meaningful for the manageable power,
        				for the 5v output voltage ,the unit is 0.01v; for the -48V output voltage, the unit is 0.1v"
        ::= { raisecomPowerOutputEntry 4 }

    raisecomPowerOutputvolupperThres     OBJECT-TYPE
        SYNTAX          Integer32(-600..600)
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION     "The threshold of the high output voltage  alarm,it is only meaningful for the manageable power,
        				for the 5v output voltage ,the unit is 0.01v; for the -48V output voltage, the unit is 0.1v"
        ::= { raisecomPowerOutputEntry 5 }

  -- other table define here
  --raisecomSubFanTable
   raisecomSubFanTable     OBJECT-TYPE
        SYNTAX          SEQUENCE OF  raisecomSubFanEntry
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION     "Fan management table."
    ::= { raisecomFan 1 }

    raisecomSubFanEntry    OBJECT-TYPE
	SYNTAX          raisecomSubFanEntry
	MAX-ACCESS      not-accessible
    STATUS          current
	DESCRIPTION     "Fan management table entry."
	INDEX { raisecomFanSlotId, raisecomSubFanId  }
    ::= { raisecomSubFanTable 1 }

    raisecomSubFanEntry ::=
        SEQUENCE {
        raisecomFanSlotId                   SlotIndex,
        raisecomSubFanId           			INTEGER,
        raisecomSubFanStatus                INTEGER,
        raisecomSubFanSpeed					INTEGER
       }

     raisecomFanSlotId          OBJECT-TYPE
        SYNTAX          SlotIndex
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Slot Index."
        ::= { raisecomSubFanEntry 1 }

     raisecomSubFanId       OBJECT-TYPE
        SYNTAX          SlotIndex
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Sub Fan Index."
        ::= { raisecomSubFanEntry 2 }

     raisecomSubFanStatus     OBJECT-TYPE
        SYNTAX             INTEGER  {
									normal(1),
									abnormal(2),
									null(3),
									unknown(4)
									}
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Fan status. Null value means that this fan is plugged out."
        ::= { raisecomSubFanEntry 3 }

     raisecomSubFanSpeed     OBJECT-TYPE
        SYNTAX          INTEGER
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Fan current speed."
        ::= { raisecomSubFanEntry 4 }


     raisecomFanMaxSpeed   OBJECT-TYPE
        SYNTAX 		        INTEGER
        MAX-ACCESS 	read-write
        STATUS current
        DESCRIPTION  "the maximum fan speed."
        DEFVAL {3300}
        ::= { raisecomFan 2 }

     raisecomFanMinSpeed   OBJECT-TYPE
        SYNTAX 		        INTEGER
        MAX-ACCESS 	read-write
        STATUS current
        DESCRIPTION  "the minimun fan speed."
        DEFVAL {900}
        ::= { raisecomFan 3 }

     raisecomFanSpeedMode   OBJECT-TYPE
        SYNTAX 		        INTEGER
        					{
        					auto(1),
        					manual(2)
        					}
        MAX-ACCESS 	read-write
        STATUS current
        DESCRIPTION  "the fan control mode ,auto means the fan speed is controled
                      by the temperature automatically,the other means controled manually."
        DEFVAL {auto}
        ::= { raisecomFan 4 }

     raisecomFanSpeedManual   OBJECT-TYPE
        SYNTAX 		        INTEGER (0..40)
        MAX-ACCESS 	read-write
        STATUS current
        DESCRIPTION  "manual control the fan speed by configurating the fan different gear."
        DEFVAL {8}
        ::= { raisecomFan 5 }

     raisecomFanSpeedGear   OBJECT-TYPE
        SYNTAX 		        INTEGER (1..8)
        MAX-ACCESS 	read-only
        STATUS current
        DESCRIPTION  "the fan speed gear."

        ::= { raisecomFan 6 }


     --raisecomCardPower
	 raisecomCardPowerTable     OBJECT-TYPE
        SYNTAX          SEQUENCE OF  RaisecomCardPowerEntry
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION     "Card power management table."
        ::= { raisecomCardPower 1 }

	 raisecomCardPowerEntry    OBJECT-TYPE
		SYNTAX          RaisecomCardPowerEntry
		MAX-ACCESS      not-accessible
    	STATUS          current
		DESCRIPTION     "card power management table entry."
		INDEX { raisecomCardPowerSlotId, raisecomCardPowerType}
    	::= { raisecomCardPowerTable 1 }

     RaisecomCardPowerEntry ::=
        SEQUENCE {
        raisecomCardPowerSlotId           		SlotIndex,
        raisecomCardPowerType                   INTEGER,
        raisecomCardPowerVolValue			    Integer32,
        raisecomCardPowerVolHighThres           Integer32,
        raisecomCardPowerVolLowThres            Integer32
       }

     raisecomCardPowerSlotId          OBJECT-TYPE
        SYNTAX          SlotIndex
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Slot Index."
        ::= { raisecomCardPowerEntry 1 }

     raisecomCardPowerType       OBJECT-TYPE
        SYNTAX          INTEGER
        				{
        				    power075v(1),
        				    power09v(2),
        				    power1v(3),
        					power12v(4),
        					power15v(5),
        					power18v(6),
							power25v(7),
							power33v(8),
							power48v(9),
							power5v(10),
							power52v(11),
							power120v(12),
							unknown(13),
							null(14),
							power125v(15),
							power29v(16)

        				}
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "card power types."
        ::= { raisecomCardPowerEntry 2 }

     raisecomCardPowerVolValue       OBJECT-TYPE
        SYNTAX          Integer32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "the current card voltage of the power type."
        ::= { raisecomCardPowerEntry 3 }

     raisecomCardPowerVolHighThres       OBJECT-TYPE
        SYNTAX          Integer32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "the high voltage threshold of the power."
        ::= { raisecomCardPowerEntry 4 }

     raisecomCardPowerVolLowThres       OBJECT-TYPE
        SYNTAX          Integer32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "the low voltage threshold of the power."
        ::= { raisecomCardPowerEntry 5 }

  --raisecomAlarmInput

   raisecomAlarmInputTable    OBJECT-TYPE
        SYNTAX          SEQUENCE OF  RaisecomAlarmInputEntry
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION     "Alarm input management table."
    ::= { raisecomAlarmInput 1 }

    raisecomAlarmInputEntry    OBJECT-TYPE
	SYNTAX          RaisecomAlarmInputEntry
	MAX-ACCESS      not-accessible
    STATUS          current
	DESCRIPTION     "Alarm input management table entry."
	INDEX { raisecomAlarmInputPortId }
    ::= { raisecomAlarmInputTable 1 }

    RaisecomAlarmInputEntry ::= SEQUENCE {
        raisecomAlarmInputPortId            Integer32,
        raisecomAlarmInputType        		INTEGER,
        raisecomAlarmInputDescr          	OCTET STRING (SIZE (0..32)),
        raisecomAlarmInputState        		INTEGER,
        raisecomAlarmInputMontiorEnable     INTEGER
        }

     raisecomAlarmInputPortId   OBJECT-TYPE
        SYNTAX          Integer32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Alarm Input port id."
        ::= { raisecomAlarmInputEntry 1 }

     raisecomAlarmInputType   OBJECT-TYPE
        SYNTAX          INTEGER
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION     "Alarm type code. 0 means that this port is unused."
        ::= { raisecomAlarmInputEntry 2 }

    raisecomAlarmInputDescr   OBJECT-TYPE
        SYNTAX          OCTET STRING (SIZE(0..32))
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION      "Alarm type description."
        ::= { raisecomAlarmInputEntry 3 }

    raisecomAlarmInputState     OBJECT-TYPE
        SYNTAX          INTEGER  {
									normal(1),
									abnormal(2),
									null(3),
									missing(4),
									unknown(5)
								  }
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "State of this input port."
        ::= { raisecomAlarmInputEntry 4 }

	raisecomAlarmInputMontiorEnable     OBJECT-TYPE
        SYNTAX          INTEGER  {
									disable(1),
									enable(2)
								  }
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION     "enable or disable the function of the port environment monitor , default is disable."
        DEFVAL {disable}
        ::= { raisecomAlarmInputEntry 5 }

  -- raisecomDeviceAlarm

	raisecomPowerMissTrap  NOTIFICATION-TYPE
          OBJECTS {raisecomPowerDeviceIndex}
          STATUS  current
           DESCRIPTION "Power device missing notification."
          ::= { raisecomDeviceAlarm 1 }

	raisecomPowerFoundTrap  NOTIFICATION-TYPE
          OBJECTS {raisecomPowerDeviceIndex}
          STATUS  current
          DESCRIPTION "Power device plugged-in notification."
          ::= { raisecomDeviceAlarm 2 }

   raisecomPowerFaultTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomPowerDeviceIndex,raisecomPowerOutputType}
           STATUS  current
           DESCRIPTION  "Power device abnormal notification."
           ::= { raisecomDeviceAlarm 3 }

   raisecomPowerFaultRecoveredTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomPowerDeviceIndex,raisecomPowerOutputType}
           STATUS  current
           DESCRIPTION  "Power device fault recovered notification."
           ::= { raisecomDeviceAlarm 4 }
   raisecomFanMissTrap  NOTIFICATION-TYPE
            OBJECTS {raisecomFanSlotId, raisecomSubFanId}
            STATUS  current
            DESCRIPTION  "Fan missing notification."
            ::= { raisecomDeviceAlarm 5 }

   raisecomFanFoundTrap  NOTIFICATION-TYPE
            OBJECTS {raisecomFanSlotId, raisecomSubFanId}
            STATUS  current
            DESCRIPTION   "Fan plugged-in notification."
            ::= { raisecomDeviceAlarm 6 }

	raisecomSubFanFaultTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomFanSlotId, raisecomSubFanId,
                    raisecomSubFanStatus, raisecomSubFanSpeed}
           STATUS  current
           DESCRIPTION   "Sub Fan abnormal notification."
           ::= { raisecomDeviceAlarm 7 }

	raisecomSubFanFaultRecoveredTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomFanSlotId, raisecomSubFanId,
                    raisecomSubFanStatus, raisecomSubFanSpeed}
           STATUS  current
           DESCRIPTION   "Sub Fan fault recovered notification."
           ::= { raisecomDeviceAlarm 8 }
	raisecomCardMissTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomSlotId, raisecomSlotExpectCardType}
           STATUS  current
           DESCRIPTION
           		"Card missing notification. Sent when no card is detected in a slot
           		and expected card type for this slot is configured. It will not be
           		sent for power devices and fans."
           ::= { raisecomDeviceAlarm 9 }

    raisecomCardMissCancelledTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomSlotId}
           STATUS  current
           DESCRIPTION  "Card plugged-in notification. It will not be
           		sent for power devices and fans."
           ::= { raisecomDeviceAlarm 10 }


	raisecomNonInstalledCardExist  NOTIFICATION-TYPE
           OBJECTS {raisecomSlotId, raisecomSlotActCardType}
           STATUS  current
           DESCRIPTION  "Non-installed card plugged-in notification.
           		The binded variable 'raisecomSlotActCardType' is currently unused.
           		It will not be sent for power devices and fans."
           ::= { raisecomDeviceAlarm 11 }

	raisecomNonInstalledCardExistCancelled  NOTIFICATION-TYPE
           OBJECTS {raisecomSlotId }
           STATUS  current
           DESCRIPTION   "Non-installed card plugged-out or installed notification. It will not be
           		sent for power devices and fans."
           ::= { raisecomDeviceAlarm 12 }

     raisecomCardTypeMisMatchTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomSlotId, raisecomSlotActCardType ,
					raisecomSlotExpectCardType }
           STATUS  current
           DESCRIPTION  "Actual card type and expected card type mismatched notification.
           It will not be sent for power devices and fans."
           ::= { raisecomDeviceAlarm 13 }

     raisecomCardTypeMisMatchCancelledTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomSlotId }
           STATUS  current
           DESCRIPTION  "Actual card type and expected card type matched notification.
           It will not be sent for power devices and fans."
           ::= { raisecomDeviceAlarm 14 }

     raisecomCardFaultTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomSlotId, raisecomSlotActCardState}
           STATUS  current
           DESCRIPTION  "Card abnormal notification. It will not be sent for power devices and fans."
           ::= { raisecomDeviceAlarm 15 }

     raisecomCardFaultRecoveredTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomSlotId }
           STATUS  current
           DESCRIPTION   "Card fault recovered notificaiton. It will not be sent for power devices and fans."
           ::= { raisecomDeviceAlarm 16 }

	 raisecomShelfTempertureThresholdCrossingTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomShelfId, raisecomNETmptAlarmThreshold}
           STATUS  current
           DESCRIPTION  "Shelf temperature threshold crossing notification."
           ::= { raisecomDeviceAlarm 17 }
     raisecomShelfTempertureRecoveredTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomShelfId, raisecomNETmptAlarmThreshold}
           STATUS  current
           DESCRIPTION  "Shelf temperature recovered notification."
           ::= { raisecomDeviceAlarm 18 }

	raisecomNonInstalledCardTypeTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomSlotId, raisecomSlotActCardType}
           STATUS  current
           DESCRIPTION  "Card type of a non-installed card notification."
           ::= { raisecomDeviceAlarm 19 }
   raisecomCardPowerFaultTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomCardPowerSlotId, raisecomSlotActCardType ,
					raisecomSlotExpectCardType }
           STATUS  current
           DESCRIPTION  "Card power fault notification."
           ::= { raisecomDeviceAlarm 20 }

   raisecomCardPowerFaultRecoveredTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomCardPowerSlotId, raisecomSlotActCardType ,
					raisecomSlotExpectCardType }
           STATUS  current
           DESCRIPTION  "Card power fault recovered notification."
           ::= { raisecomDeviceAlarm 21 }

	raisecomExternalAlarmTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomAlarmInputPortId, raisecomAlarmInputType,
                    raisecomAlarmInputDescr, raisecomAlarmInputState}
           STATUS  current
           DESCRIPTION  "External alarm notification."
           ::= { raisecomDeviceAlarm 22 }

	raisecomExternalAlarmRecoverdTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomAlarmInputPortId, raisecomAlarmInputType,
                    raisecomAlarmInputDescr, raisecomAlarmInputState}
           STATUS  current
           DESCRIPTION  "External alarm recovered notification."
           ::= { raisecomDeviceAlarm 23 }

    raisecomSubFanAgingTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomFanSlotId, raisecomSubFanId, raisecomSubFanStatus,
                    raisecomSubFanSpeed,raisecomFanSpeedGear}
           STATUS  current
           DESCRIPTION  "Sub Fan aging notification."
           ::= { raisecomDeviceAlarm 24 }

    raisecomSubFanAgingRecoveredTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomFanSlotId, raisecomSubFanId, raisecomSubFanStatus,
                    raisecomSubFanSpeed,raisecomFanSpeedGear}
           STATUS  current
           DESCRIPTION  "Sub Fan aging recovered notification."
           ::= { raisecomDeviceAlarm 25 }

 --   raisecomPowerTypeMismatchedTrap  NOTIFICATION-TYPE
 --          OBJECTS {raisecomPowerDeviceIndex, raisecomPowerExpectType, raisecomPowerActualType}
 --          STATUS  current
 --          DESCRIPTION  "Power type mismatched notification."
 --          ::= { raisecomDeviceAlarm 26 }

 --   raisecomPowerTypeMismatchedRecoveredTrap  NOTIFICATION-TYPE
 --          OBJECTS {raisecomPowerDeviceIndex}
  --         STATUS  current
  --         DESCRIPTION  "Power type mismatched recovered notification."
  --         ::= { raisecomDeviceAlarm 27 }

    raisecomPowerVoltageInputTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomPowerDeviceIndex, raisecomPowerDeviceInputType,
                    raisecomPowerInputvol, raisecomPowerInputvolalarmState}
           STATUS  current
           DESCRIPTION  "Input voltage abnormal notification."
           ::= { raisecomDeviceAlarm 28 }

    raisecomPowerVoltageInputRecoveredTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomPowerDeviceIndex, raisecomPowerDeviceInputType,
                    raisecomPowerInputvol, raisecomPowerInputvolalarmState}
           STATUS  current
           DESCRIPTION  "Input voltage abnormal recovered notification, it is only meaningful for the manageable power."
           ::= { raisecomDeviceAlarm 29 }

    raisecomPowerVoltageOutputTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomPowerDeviceIndex, raisecomPowerOutputType,
                    raisecomPowerOutputvol, raisecomPowerStatus }
           STATUS  current
           DESCRIPTION  "output voltage abnormal notification, it is only meaningful for the manageable power."
           ::= { raisecomDeviceAlarm 30 }

    raisecomPowerVoltageOutputRecoveredTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomPowerDeviceIndex, raisecomPowerOutputType,
                    raisecomPowerOutputvol, raisecomPowerStatus }
           STATUS  current
           DESCRIPTION  "output voltage abnormal recovered notification, it is only meaningful for the manageable power."
           ::= { raisecomDeviceAlarm 31 }

    raisecomPowerTemperatureTooHighTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomPowerDeviceIndex, raisecomPowertemperature,
                    raisecomPowerTemperatureThres}
           STATUS  current
           DESCRIPTION  "power temperature too high notification, it is only meaningful for the manageable power."
           ::= { raisecomDeviceAlarm 32 }

    raisecomPowerTemperatureTooHighRecoveredTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomPowerDeviceIndex, raisecomPowertemperature,
                    raisecomPowerTemperatureThres}
           STATUS  current
           DESCRIPTION  "power temperature too high recovered notification, it is only meaningful for the manageable power."
           ::= { raisecomDeviceAlarm 33 }
    raisecomCardLoadConfigFailedTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomSlotId, raisecomSlotActCardType ,
					raisecomSlotExpectCardType}
           STATUS  current
           DESCRIPTION  "Card config loading failed notification."
           ::= { raisecomDeviceAlarm 34 }

    raisecomCardVersionMismatchTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomSlotId, raisecomSlotActCardType ,
					raisecomSlotExpectCardType}
           STATUS  current
           DESCRIPTION  "Card version mismatched notification."
           ::= { raisecomDeviceAlarm 35 }

    raisecomCardVersionMismatchRecoveredTrap  NOTIFICATION-TYPE
           OBJECTS {raisecomSlotId, raisecomSlotActCardType ,
					raisecomSlotExpectCardType}
           STATUS  current
           DESCRIPTION  "Card version-mismatch recovered notification."
           ::= { raisecomDeviceAlarm 36 }