-- RBN-ENVMON-MIB	Environmental Monitor MIB
--
-- Copyright (c) 1999-2007, 2010-2011 Ericsson AB
-- All rights reserved.
-- 
-- *****************************************************************

RBN-ENVMON-MIB DEFINITIONS ::= BEGIN

IMPORTS
	MODULE-IDENTITY,
	OBJECT-TYPE,
	NOTIFICATION-TYPE,
	Unsigned32,
	Integer32
		FROM SNMPv2-SMI
	DisplayString,
	TruthValue,
	TEXTUAL-CONVENTION
		FROM SNMPv2-TC
	MODULE-COMPLIANCE,
	OBJECT-GROUP,
	NOTIFICATION-GROUP
		FROM SNMPv2-CONF
	entPhysicalIndex
		FROM ENTITY-MIB
	rbnMgmt
		FROM RBN-SMI;

rbnEnvMonMIB MODULE-IDENTITY
        LAST-UPDATED    "201210030000Z" -- October 3, 2012
	ORGANIZATION	"Ericsson AB."
	CONTACT-INFO
		"	Ericsson AB.

		Postal:	100 Headquarters Dr.
			San Jose, CA  95134
			USA

		 Phone:	+1 408 750 5000
		   Fax: +1 408 750 5599

		"
	DESCRIPTION
		"The MIB used to genericially manage Environmental
		Monitor functionality on network devices."
               
        REVISION        "201210030000Z" -- October 3, 2012
        DESCRIPTION
                "Removed DISPLAY-HINT from RbnVoltage and RbnFanSpeed."

        REVISION        "201101191800Z" -- Jan 19, 2011
        DESCRIPTION
                "Update CONTACT-INFO & ORGANIZATION. "

        REVISION        "201011110000Z" -- Nov 11, 2010
        DESCRIPTION
                "Add new Table rbnEntityTempSensorTable. This will display 
                the TempSensor Details for all the entities. "

	REVISION	"200601160000Z" -- January 16, 2006
	DESCRIPTION
		"Add textual convention RbnFanSpeed.  Add new OIDs:
			rbnFanUnitID
			rbnFanUnitDescr
			rbnFanSpeedCurrent
			rbnEnvMonFanSpeedObjectGroup
			rbnEnvMonMIBComplianceV4
		"
	REVISION	"200206050000Z" -- June 5, 2002
	DESCRIPTION
		"Update/correct CONTACT-INFO. Fix syntax errors on IMPORTS list,
		ranges on Integer32, and size for DisplayString types.
		Restore the incorrectly deprecated OIDs to current, since they
		are still supported."
	REVISION        "200107250000Z" -- July 25, 2001
	DESCRIPTION
		"Added new OIDs:
			rbnFanStatus
			rbnPowerStatus
			rbnFanStatusChange
			rbnPowerStatusChange
			rbnEnvMonMIBObjectGroupV2
			rbnEnvMonMIBNotificationGroupV2
			rbnEnvMonMIBComplianceV3
		 Deprecated the OIDs:
			rbnFanFail
			rbnPowerFail
			rbnFanFailChange
			rbnPowerFailChange
			rbnEnvMonMIBObjectGroup
			rbnEnvMonMIBNotificationGroup
			rbnEnvMonMIBComplianceV2
		"
	REVISION	"200004240000Z" -- May 24, 2000
	DESCRIPTION
		"Added voltage and temperature sensor tables."

	REVISION	"199903100000Z" -- Mar 10, 1999
	DESCRIPTION
            "Initial version."
	::= { rbnMgmt 4 }

rbnEnvMonMIBNotifications OBJECT IDENTIFIER
	::= { rbnEnvMonMIB 0 }

rbnEnvMonMIBObjects OBJECT IDENTIFIER
	::= { rbnEnvMonMIB 1 }

rbnEnvMonMIBConformance OBJECT IDENTIFIER
	::= { rbnEnvMonMIB 2 }


-- Textual Conventions

RbnVoltage ::= TEXTUAL-CONVENTION
	STATUS       current
	DESCRIPTION
		"Represents a voltage value. The value is millivolts.
		 For example, a voltage of 5.5V would be represented
		 by the value 5500."
	SYNTAX       Unsigned32 (0..50000)

RbnTemperature ::= TEXTUAL-CONVENTION
	DISPLAY-HINT "d"
	STATUS       current
	DESCRIPTION
		"Represents a temperature, in degrees Celsius. In the
		 unlikely event that the temperature to be reported is
		 less than 0 degrees Celsius, a value of 0 will be
		 used. Likewise, if the temperature is greater than
		 100, a value of 100 will be used."
	SYNTAX       Unsigned32 (0..100)

RbnFanSpeed ::= TEXTUAL-CONVENTION
	STATUS       current
	DESCRIPTION
		"Represents a fan speed value in units of Revolutions Per
		Minute(RPM)."
	SYNTAX       Unsigned32

-- MIB Objects

rbnFanStatusTable OBJECT-TYPE
	SYNTAX	    SEQUENCE OF RbnFanStatusEntry
	MAX-ACCESS  not-accessible
	STATUS	    current
	DESCRIPTION
		"This table contains one row per fan test point.
		Note that there is not necessarily a one-to-one
		relationship between fan test points and fan
		assemblies; a single test point may be used to
		monitor the status of multiple fans."
	::= { rbnEnvMonMIBObjects 1 }

rbnFanStatusEntry OBJECT-TYPE
	SYNTAX	    RbnFanStatusEntry
	MAX-ACCESS  not-accessible
	STATUS	    current
	DESCRIPTION
		"Information about a particular fan test point"
	INDEX	{ rbnFanIndex }
	::= { rbnFanStatusTable 1 }

RbnFanStatusEntry ::= SEQUENCE {
	rbnFanIndex	Integer32,
	rbnFanDescr	DisplayString,
	rbnFanFail	TruthValue,
	rbnFanStatus	INTEGER
}

rbnFanIndex OBJECT-TYPE
	SYNTAX	    Integer32(1..2147483647)
	MAX-ACCESS  not-accessible
	STATUS	    current
	DESCRIPTION
		"The index of a fan test point."
	::= { rbnFanStatusEntry 1 }

rbnFanDescr OBJECT-TYPE
	SYNTAX	    DisplayString(SIZE(0..32))
	MAX-ACCESS  read-only
	STATUS	    current
	DESCRIPTION
		"The description of a fan test point.  If an instance of
		this object is associated with a single fan assembly,
		then the value of this object should be the same as the
		name by which the assembly is normally referenced.  If
		an instance is associated with multiple fan assemblies,
		then the value of this object should contain the names
		of all of the fan assemblies being monitored."
	::= { rbnFanStatusEntry 2 }

rbnFanFail OBJECT-TYPE
	SYNTAX	    TruthValue
	MAX-ACCESS  read-only
	STATUS	    deprecated 
	DESCRIPTION
		"The status of a fan test point.  If an instance of
		this object has the value true, then a fan monitored
		by the test point has failed.  If an instance of
		this object has the value false, then the fan (or fans)
		monitored by the test point are operational."
	::= { rbnFanStatusEntry 3 }

rbnFanStatus OBJECT-TYPE
	SYNTAX	    INTEGER {
			normal(1),
			failed(2),
			absent(3),
			unknown(4)
		    }
	MAX-ACCESS  read-only
	STATUS	    current
	DESCRIPTION
		"The status of a fan test point.  If an instance of
		this object has the value normal, then the fan (or 
		fans) monitored by the test point is operational.  If
		an instance of this object has the value failed, then 
		the fan (or fans) monitored by the test point has 
		failed. If an instance of this object has the value 
		absent, then the fan (or fans) monitored by this test 
		point is not present. If an instance of this object has
		the value unknown, then the test point is unable to
		monitor the fan (or fans)."
	::= { rbnFanStatusEntry 4 }

rbnPowerStatusTable OBJECT-TYPE
	SYNTAX	    SEQUENCE OF RbnPowerStatusEntry
	MAX-ACCESS  not-accessible
	STATUS	    current
	DESCRIPTION
		"This table contains one row per power test point.
		Note that there is not necessarily a one-to-one
		relationship between power test points and power
		supply assemblies; a single test point may be used
		to monitor the status of multiple power supplies."
	::= { rbnEnvMonMIBObjects 2 }

rbnPowerStatusEntry OBJECT-TYPE
	SYNTAX	    RbnPowerStatusEntry
	MAX-ACCESS  not-accessible
	STATUS	    current
	DESCRIPTION
		"Information about a particular power test point"
	INDEX	{ rbnPowerIndex }
	::= { rbnPowerStatusTable 1 }

RbnPowerStatusEntry ::= SEQUENCE {
	rbnPowerIndex	Integer32,
	rbnPowerDescr	DisplayString,
	rbnPowerFail	TruthValue,
	rbnPowerStatus	INTEGER
}

rbnPowerIndex OBJECT-TYPE
	SYNTAX	    Integer32(1..2147483647)
	MAX-ACCESS  not-accessible
	STATUS	    current
	DESCRIPTION
		"The index of a power test point."
	::= { rbnPowerStatusEntry 1 }

rbnPowerDescr OBJECT-TYPE
	SYNTAX	    DisplayString(SIZE(0..32))
	MAX-ACCESS  read-only
	STATUS	    current
	DESCRIPTION
		"The description of a power supply test point.  If an
		instance of this object is associated with a single
		power supply assembly, then the value of this object
		should be the same as the name by which the assembly
		is normally referenced.  If an instance is associated
		with multiple power supply assemblies, then the value
		of this object should contain the names of all of the
		power supply assemblies being monitored."
	::= { rbnPowerStatusEntry 2 }

rbnPowerFail OBJECT-TYPE
	SYNTAX	    TruthValue
	MAX-ACCESS  read-only
	STATUS	    deprecated 
	DESCRIPTION
		"The status of a power test point.  If an instance of
		this object has the value true, then a power supply
		monitored by the test point has failed.  If an instance
		of this object has the value false, then the power
		supply (or supplies) monitored by the test point are
		operational."
	::= { rbnPowerStatusEntry 3 }

rbnPowerStatus OBJECT-TYPE
	SYNTAX	    INTEGER {
			normal(1),
			failed(2),
			absent(3),
			unknown(4)
		    }
	MAX-ACCESS  read-only
	STATUS	    current
	DESCRIPTION
		"The status of a power test point.  If an instance of
		this object has the value normal, then the power 
		supply (or supplies) monitored by the test point is 
		operational.  If an instance of this object has the 
		value failed, then the power supply (or supplies)
		monitored by the test point has failed. If an instance
		of this object has the value absent, then the power
		supply (or supplies) monitored by this test point is 
		not present. If an instance of this object has
		the value unknown, then the test point is unable to
		monitor the power supply (or supplies)."
	::= { rbnPowerStatusEntry 4 }

rbnVoltageSensorTable OBJECT-TYPE
	SYNTAX	    SEQUENCE OF RbnVoltageSensorEntry
	MAX-ACCESS  not-accessible
	STATUS	    current
	DESCRIPTION
		"This table contains one row per voltage test point.
		 Each physical entity (e.g. cards) in the system may
		 contain zero or more voltage test points."
	::= { rbnEnvMonMIBObjects 3 }

rbnVoltageSensorEntry OBJECT-TYPE
	SYNTAX	RbnVoltageSensorEntry
	MAX-ACCESS  not-accessible
	STATUS	    current
	DESCRIPTION
		"Information about a particular voltage test point."
	INDEX	{ entPhysicalIndex, rbnVoltageIndex }
	::= { rbnVoltageSensorTable 1 }

RbnVoltageSensorEntry ::= SEQUENCE {
	rbnVoltageIndex   Integer32,
	rbnVoltageDescr   DisplayString,
	rbnVoltageDesired RbnVoltage,
	rbnVoltageCurrent RbnVoltage
}

rbnVoltageIndex OBJECT-TYPE
	SYNTAX      Integer32(1..2147483647)
	MAX-ACCESS  not-accessible
	STATUS	    current
	DESCRIPTION
		"An arbitrary value which uniquely identifies a
		 voltage test point on a particular physical entity.
		 Index values for different test points are not
		 necessarily contiguous."
	::= { rbnVoltageSensorEntry 1 }

rbnVoltageDescr OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..48))
	MAX-ACCESS  read-only
	STATUS      current
	DESCRIPTION
		"The description of a voltage test point. Typically
		 an instance of this object will hold a user-friendly
		 description of the physical entity and the level of
		 voltage being monitored by this test point."
	::= { rbnVoltageSensorEntry 2 }

rbnVoltageDesired OBJECT-TYPE
	SYNTAX      RbnVoltage
	UNITS	    "millivolts"
	MAX-ACCESS  read-only
	STATUS	    current
	DESCRIPTION
		"The desired voltage level for this test point. If
		 the monitored voltage level (rbnVoltageCurrent) is
		 equal to this value, then the system is performing
		 as designed."
	::= { rbnVoltageSensorEntry 3 }

rbnVoltageCurrent OBJECT-TYPE
	SYNTAX      RbnVoltage
	UNITS	    "millivolts"
	MAX-ACCESS  read-only
	STATUS	    current
	DESCRIPTION
		"The current voltage level at this test point."
	::= { rbnVoltageSensorEntry 4 }

rbnCpuTempSensorTable OBJECT-TYPE
	SYNTAX      SEQUENCE OF RbnCpuTempSensorEntry
	MAX-ACCESS  not-accessible
	STATUS	    deprecated 
	DESCRIPTION
		"This table contains one row per CPU temperature
		 sensor. Each physical entity in the system may have
		 zero or more CPUs. Each of those CPUs that has a
		 temperature sensor will show up here."
	::= { rbnEnvMonMIBObjects 4 }

rbnCpuTempSensorEntry OBJECT-TYPE
	SYNTAX      RbnCpuTempSensorEntry
	MAX-ACCESS  not-accessible
	STATUS	    deprecated 
	DESCRIPTION
		"Information about a particular CPU temperature test
		 point."
	INDEX   { entPhysicalIndex, rbnCpuTempIndex }
	::= { rbnCpuTempSensorTable 1 }

RbnCpuTempSensorEntry ::= SEQUENCE {
	rbnCpuTempIndex   Integer32,
	rbnCpuTempDescr   DisplayString,
	rbnCpuTempCurrent RbnTemperature
}

rbnCpuTempIndex OBJECT-TYPE
	SYNTAX      Integer32(1..2147483647)
	MAX-ACCESS  not-accessible
	STATUS	    deprecated
	DESCRIPTION
		"An arbitrary value which uniquely identifies a CPU on
		 a particular physical entity.  Index values for
		 different CPUs are not necessarily contiguous."
	::= { rbnCpuTempSensorEntry 1 }

rbnCpuTempDescr OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..48))
	MAX-ACCESS  read-only
	STATUS	    deprecated
	DESCRIPTION
		"The description of a CPU temperature test
		 point. Typically an instance of this object will hold
		 a user-friendly description of the physical entity
		 and a description of the CPU being monitored by this
		 test point."
	::= { rbnCpuTempSensorEntry 2 }

rbnCpuTempCurrent OBJECT-TYPE
	SYNTAX      RbnTemperature
	UNITS	    "degrees"
	MAX-ACCESS  read-only
	STATUS	    deprecated
	DESCRIPTION
		"The current temperature of this CPU."
	::= { rbnCpuTempSensorEntry 3 }

rbnFanSpeedTable OBJECT-TYPE
	SYNTAX	    SEQUENCE OF RbnFanSpeedEntry
	MAX-ACCESS  not-accessible
	STATUS	    current
	DESCRIPTION
		"This table contains one row per fan unit within a fan
		test point."
	::= { rbnEnvMonMIBObjects 5 }

rbnFanSpeedEntry OBJECT-TYPE
	SYNTAX	    RbnFanSpeedEntry
	MAX-ACCESS  not-accessible
	STATUS	    current
	DESCRIPTION
		"Information about a particular fan unit within a fan
                test point."
	INDEX	{ rbnFanIndex, rbnFanUnitID }
	::= { rbnFanSpeedTable 1 }

RbnFanSpeedEntry ::= SEQUENCE {
	rbnFanUnitID	    Integer32,
	rbnFanUnitDescr	    DisplayString,
	rbnFanSpeedCurrent  RbnFanSpeed
}

rbnFanUnitID OBJECT-TYPE
	SYNTAX	    Integer32(1..2147483647)
	MAX-ACCESS  not-accessible
	STATUS	    current
	DESCRIPTION
		"This is the fan identification number that describes the
		specific location of the fan unit within a fan test point."
	::= { rbnFanSpeedEntry 1 }

rbnFanUnitDescr OBJECT-TYPE
	SYNTAX	    DisplayString(SIZE(0..32))
	MAX-ACCESS  read-only
	STATUS	    current
	DESCRIPTION
		"The description of the fan unit within a fan test point."
	::= { rbnFanSpeedEntry 2 }

rbnFanSpeedCurrent OBJECT-TYPE
	SYNTAX	    RbnFanSpeed
	MAX-ACCESS  read-only
	STATUS	    current
	DESCRIPTION
		"The current speed of this fan unit."
	::= { rbnFanSpeedEntry 3 }

rbnEntityTempSensorTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF RbnEntityTempSensorEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                "This table contains one row per temperature
                 sensor on the physical entity."
        ::= { rbnEnvMonMIBObjects 6 }

rbnEntityTempSensorEntry OBJECT-TYPE
        SYNTAX      RbnEntityTempSensorEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                "Information about a particular temperature test
                 point."
        INDEX   { entPhysicalIndex, rbnEntityTempIndex }
        ::= { rbnEntityTempSensorTable 1 }

RbnEntityTempSensorEntry ::= SEQUENCE {
        rbnEntityTempIndex   Integer32,
        rbnEntityTempDescr   DisplayString,
        rbnEntityTempCurrent RbnTemperature
}

rbnEntityTempIndex OBJECT-TYPE
        SYNTAX      Integer32(1..2147483647)
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                "An arbitrary value which uniquely identifies a
                 particular physical entity.  Index values are 
                 not necessarily contiguous."
        ::= { rbnEntityTempSensorEntry 1 }

rbnEntityTempDescr OBJECT-TYPE
        SYNTAX      DisplayString (SIZE (0..48))
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "The description of a temperature test
                 point. Typically an instance of this object will hold
                 a user-friendly description of the physical entity
                 being monitored by this test point."
        ::= { rbnEntityTempSensorEntry 2 }

rbnEntityTempCurrent OBJECT-TYPE
        SYNTAX      RbnTemperature
        UNITS       "degrees Celsius"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "The current temperature of this entity in degrees Celsius."
        ::= { rbnEntityTempSensorEntry 3 }

-- Notifications

rbnFanFailChange NOTIFICATION-TYPE
	OBJECTS	    { rbnFanFail }
	STATUS	    deprecated 
	DESCRIPTION
		"A rbnFanFailChange notification signifies
		that the value of an instance of rbnFanFail
		has changed."
	::= { rbnEnvMonMIBNotifications 1 }

rbnPowerFailChange NOTIFICATION-TYPE
	OBJECTS	    { rbnPowerFail }
	STATUS	    deprecated 
	DESCRIPTION
		"A rbnPowerFailChange notification signifies
		that the value of an instance of rbnPowerFail
		has changed"
	::= { rbnEnvMonMIBNotifications 2 }

rbnFanStatusChange NOTIFICATION-TYPE
	OBJECTS	    { rbnFanStatus }
	STATUS	    current
	DESCRIPTION
		"A rbnFanStatusChange notification signifies
		that the value of an instance of rbnFanStatus
		has changed."
	::= { rbnEnvMonMIBNotifications 3 }

rbnPowerStatusChange NOTIFICATION-TYPE
	OBJECTS	    { rbnPowerStatus }
	STATUS	    current
	DESCRIPTION
		"A rbnPowerStatusChange notification signifies
		that the value of an instance of rbnPowerStatus
		has changed"
	::= { rbnEnvMonMIBNotifications 4 }

-- Conformance Statements

rbnEnvMonMIBGroups OBJECT IDENTIFIER
	::= { rbnEnvMonMIBConformance 1 }

rbnEnvMonMIBCompliances OBJECT IDENTIFIER
	::= { rbnEnvMonMIBConformance 2 }

rbnEnvMonMIBObjectGroup OBJECT-GROUP
	OBJECTS	    {	rbnFanDescr, rbnFanFail,
			rbnPowerDescr, rbnPowerFail
		    }
	STATUS	    deprecated 
	DESCRIPTION
		"A collection of objects providing
		environmental monitor information."
	::= { rbnEnvMonMIBGroups 1 }

rbnEnvMonMIBNotificationGroup NOTIFICATION-GROUP
	NOTIFICATIONS {	rbnFanFailChange,
			rbnPowerFailChange
		    }
	STATUS	    deprecated 
	DESCRIPTION
		"A collection of notifications providing
		fan and power environmental monitor information."
	::= { rbnEnvMonMIBGroups 2 }

rbnEnvMonVoltageObjectGroup OBJECT-GROUP
	OBJECTS	    {	rbnVoltageDescr, rbnVoltageDesired,
			rbnVoltageCurrent
		    }
	STATUS	    current
	DESCRIPTION
		"A collection of objects providing voltage
		environmental monitor information."
	::= { rbnEnvMonMIBGroups 3 }

rbnEnvMonTempObjectGroup OBJECT-GROUP
	OBJECTS	    {	rbnCpuTempDescr, rbnCpuTempCurrent
		    }
	STATUS	   deprecated   
	DESCRIPTION
		"A collection of objects providing temperature
		environmental monitor information."
	::= { rbnEnvMonMIBGroups 4 }

rbnEnvMonMIBObjectGroupV2 OBJECT-GROUP
	OBJECTS	    {	rbnFanDescr, rbnFanStatus,
			rbnPowerDescr, rbnPowerStatus
		    }
	STATUS	    current
	DESCRIPTION
		"A collection of objects providing
		environmental monitor information."
	::= { rbnEnvMonMIBGroups 5 }

rbnEnvMonMIBNotificationGroupV2 NOTIFICATION-GROUP
	NOTIFICATIONS {	rbnFanStatusChange,
			rbnPowerStatusChange
		    }
	STATUS	    current
	DESCRIPTION
		"A collection of notifications providing
		fan and power environmental monitor information."
	::= { rbnEnvMonMIBGroups 6 }

rbnEnvMonFanSpeedObjectGroup OBJECT-GROUP
	OBJECTS	    {	rbnFanUnitDescr, rbnFanSpeedCurrent
		    }
	STATUS	    current
	DESCRIPTION
		"A collection of objects providing fan speed
		environmental monitor information."
	::= { rbnEnvMonMIBGroups 7 }

rbnEnvMonEntityObjectGroup OBJECT-GROUP
        OBJECTS     {   rbnEntityTempDescr, rbnEntityTempCurrent
                    }
        STATUS      current
        DESCRIPTION
                "A collection of objects providing fan speed
                environmental monitor information."
        ::= { rbnEnvMonMIBGroups 8 }

rbnEnvMonMIBCompliance MODULE-COMPLIANCE
	STATUS	    obsolete
	DESCRIPTION
		"The compliance statement for the EnvMon MIB"
	MODULE	    -- this module
	GROUP	    rbnEnvMonMIBObjectGroup
	DESCRIPTION
		"This group is mandatory for devices which contain
		Environmental Monitoring capabilities"
	GROUP	    rbnEnvMonMIBNotificationGroup
	DESCRIPTION
		"This group is mandatory for devices which contain
		Environmental Monitoring capabilities"
	::= { rbnEnvMonMIBCompliances 1 }

rbnEnvMonMIBComplianceV2 MODULE-COMPLIANCE
	STATUS	    deprecated 
	DESCRIPTION
		"The compliance statement for the EnvMon MIB"

	MODULE	    -- this module
	GROUP	    rbnEnvMonMIBObjectGroup
	DESCRIPTION
		"This group is mandatory for devices which contain
		Environmental Monitoring capabilities"
	GROUP	    rbnEnvMonMIBNotificationGroup
	DESCRIPTION
		"This group is mandatory for devices which contain
		Environmental Monitoring capabilities"
	GROUP	    rbnEnvMonVoltageObjectGroup
	DESCRIPTION
		"This group is mandatory for devices which are capable
		 of sensing system voltages."
	GROUP	    rbnEnvMonTempObjectGroup
	DESCRIPTION
		"This group is mandatory for devices which are capable
		 of sensing system temperatures."
	::= { rbnEnvMonMIBCompliances 2 }

rbnEnvMonMIBComplianceV3 MODULE-COMPLIANCE
	STATUS	    deprecated 
	DESCRIPTION
		"The compliance statement for the EnvMon MIB"
	MODULE	    -- this module
	GROUP	    rbnEnvMonMIBObjectGroupV2
	DESCRIPTION
		"This group is mandatory for devices which contain
		Environmental Monitoring capabilities"
	GROUP	    rbnEnvMonMIBNotificationGroupV2
	DESCRIPTION
		"This group is mandatory for devices which contain
		Environmental Monitoring capabilities"
	GROUP	    rbnEnvMonVoltageObjectGroup
	DESCRIPTION
		"This group is mandatory for devices which are capable
		 of sensing system voltages."
	GROUP	    rbnEnvMonTempObjectGroup
	DESCRIPTION
		"This group is mandatory for devices which are capable
		 of sensing system temperatures."
	::= { rbnEnvMonMIBCompliances 3 }

rbnEnvMonMIBComplianceV4 MODULE-COMPLIANCE
	STATUS	    deprecated 
	DESCRIPTION
		"The compliance statement for the EnvMon MIB"
	MODULE	    -- this module
	GROUP	    rbnEnvMonMIBObjectGroupV2
	DESCRIPTION
		"This group is mandatory for devices which contain
		Environmental Monitoring capabilities"
	GROUP	    rbnEnvMonMIBNotificationGroupV2
	DESCRIPTION
		"This group is mandatory for devices which contain
		Environmental Monitoring capabilities"
	GROUP	    rbnEnvMonVoltageObjectGroup
	DESCRIPTION
		"This group is mandatory for devices which are capable
		 of sensing system voltages."
	GROUP	    rbnEnvMonTempObjectGroup
	DESCRIPTION
		"This group is mandatory for devices which are capable
		 of sensing system temperatures."
	GROUP	    rbnEnvMonFanSpeedObjectGroup
	DESCRIPTION
		"This group is mandatory for SNMP entities which are
                capable of sensing fan speeds."
	::= { rbnEnvMonMIBCompliances 4 }


rbnEnvMonMIBComplianceV5 MODULE-COMPLIANCE
        STATUS      current
        DESCRIPTION
                "The compliance statement for the EnvMon MIB"
        MODULE      -- this module
        GROUP       rbnEnvMonMIBObjectGroupV2
        DESCRIPTION
                "This group is mandatory for devices which contain
                Environmental Monitoring capabilities"
        GROUP       rbnEnvMonMIBNotificationGroupV2
        DESCRIPTION
                "This group is mandatory for devices which contain
                Environmental Monitoring capabilities"
        GROUP       rbnEnvMonVoltageObjectGroup
        DESCRIPTION
                "This group is mandatory for devices which are capable
                 of sensing system voltages."
        GROUP       rbnEnvMonFanSpeedObjectGroup
        DESCRIPTION
                "This group is mandatory for SNMP entities which are
                capable of sensing fan speeds."
        GROUP       rbnEnvMonEntityObjectGroup
        DESCRIPTION
                "This group is mandatory for devices which contain
                Environmental Monitoring capabilities, also applicable to SSE
                card and disks"

        ::= { rbnEnvMonMIBCompliances 5 }

END